Contec PM50 Ambulatory Blood Pressure Monitor,NIBP SPO2 PR Test for Adult&Child

CHF 347.80 Sofort-Kaufen oder Preisvorschlag 4d 16h, Kostenloser Versand, 14-Day Rücknahmen, Kostenloser PayPal-Käuferschutz in unbegrenzter Höhe.

Verkäufer: mediconsultant10 (388) 100%, Artikelstandort: Qinhuangdao, Versand nach: Americas, Europe, Asia, AU, Artikelnummer: 322030454653 Click here to get free ebay templates at Auctiva.com PM50 24 hour Automatic Ambulatory Blood Pressure, Blood Oxygen Saturation, Pulse Rate Medical Patient Monitor Buy Safe Product! The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE: The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, We will verify your status as an authorized purchaser of this item before shipping of the item. PM50 is a multifunctional patient monitor, it can monitor SPO2 and NIBP for a long time, and applies to the hospital wards or family daily health care. Features Compact and portable, easy to use With Integrative SpO2 Probe Double working modes, monitoring function and 24 hours ambulatory NIBP measure function can be flexibly set. NIBP and SpO2 can be monitored for a long time NIBP and SpO2 data record for large capacity With friendly user interface, the user can see list menu and review measure results The device can display low power information, alarm information, error information and time information richly Parameter alarm function is optional Patient information can be flexibly set Case management function. PC software can achieve data review, analysis measure results, seeing trend, printing reports and other functions Performance NIBP Measure Method: Oscillometry Measure Mode: The upper arm measure Measure range: ADULT: SYS: 40mmHg~270mmHg MAP:20mmHg~235mmHg DIA: 10mmHg~215mmHg PEDIATRIC: SYS: 40mmHg~200mmHg MAP: 20mmHg~165mmHg DIA: 10mmHg~150mmHg NEONATAL: SYS: 40mmHg~135mmHg MAP: 20mmHg~110mmHg DIA: 10mmHg~100mmHg Automatic measure Interval: 5,10,15,20,30,45,60,90,120 minutes Resolution: 1mmHg Accuracy: ±3mmHg Increasing pressure mode: force pump increases pressure automatically Reducing pressure mode: self-motion ladder reducing pressure mode Alarm parameter: SYS / MAP / DIA SPO2 Measure range: 0%~100% (Resolution:1%) Accuracy: 70~100%, ±2%, below 70% unspecified Error in Weak Filling Condition:SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ±4%, pulse rate error is ±2 bpm or ±2% (select larger). Resistance to surrounding light:The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1% Pulse Rate Measuring range: 0bpm~250bpm Resolution: 1bpm Accuracy: ±2 bpm or ±2% (select larger) Display: 2.4" TFT color LCD Power: DC 3V(Two "AA", 1.5V Alkali Battery) Product safety type: Type BF applied part (Internally powered, defibrillation-proof) Physics speciality Dimension: 128mm*69mm*36 mm Weight: Condition: New, Brand: Contec, Model: PM50, MPN: PM50, Country/Region of Manufacture: China, Country of Manufacture: China

agmalvideo.com Insights agmalvideo.com Exklusiv
  •  Popularität - 761 blicke, 0.7 views per day, 1,016 days on eBay. Super hohe von blicke. 0 verkauft, 10 verfügbar.
  •  Preis -
  •  Verkäufer - 388+ artikel verkauft. 0% negativ bewertungen. Großer Verkäufer mit sehr gutem positivem Rückgespräch und über 50 Bewertungen.
Ähnliche Artikel Items
Sitemap